MIL-DTL-10958G
sealed and the sample size shall be the number of units indicated by inspection level S-1. The
cube test shall be determined initially on the individual sample units and the analytical
characteristics shall be performed on a composite sample derived from the sample units used to
perform the cube test. Each result shall be reported to the same decimal place or unit as
specified in the pertinent requirements. One or more test failures for analytical characteristics or
cube test failure shall be cause for rejection of the lot.
4.5 Tests. Test procedures and controls which differ from those specified herein, may be used
by the contractor if they provide a quality assurance equivalent to those specified. If the
Government contracting officer determines that such procedures and controls do not provide, as
a minimum, such quality assurance, the contractor will use the test procedures set forth herein.
In case of dispute as to test results, the test methods specified herein will govern.
* 4.5.1 Analytical testing. Analytical testing shall be in accordance with the methods from the
publications listed below:
Test
Method
Fat
15.11 1/
Salt
15.11 1/
Moisture
15.11 1/
Peroxide value
Cd 8b-90 2/
Fat stability
Cd 12-57 2/
(active oxygen
method)
Propyl gallate
Ce 6-86 2/
Butylated hydroxyanisole
Ce 6-86 2/
Butylated hydroxytoluene
Ce 6-86 2/
Solid fat index
Cd 10-57 2/
7.8 1/
Coliform
Yeast and Mold
8.10 1/
Standard plate count
6.2 1/
1/
E. coli
1/ Standard Methods for the Examination of Dairy Products.
2/ Methods of the American Oil Chemists' Society.
4.5.2 Calcium Disodium EDTA test. The procedure for determination of calcium disodium
EDTA shall be as follows:
Method of Analysis for Food Additive Calcium Disodium EDTA
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business